Installing the Platter
Please ensure that the point of the triangle hold in the upper teflon bearing is correctly orientated to
the motor pulley. See Fig (10). If necessary consult your dealer.
Fill the bearing with synthetic oil supplied to a level of approx 5mm (1/4”) above the bottom Teflon
bearing, this is not critical. Do not overfill. Over-filling the bearing will cause the oil to overflow the
bearing housing when the platter spindle is lowered into the bearing housing. Gently lower platter into
bearing. See Fig (11) - (12). It is most important that spindle is located correctly in the centre of the
lower thrust bearing. Failure to locate the pivot point of the spindle correctly will cause the platter to
rotate abnormally. The spindle has been designed to protrude through the platter to provide a central
lifting point that enables the user to easily achieve this.
Important: The unique design of the zero clearance Well Tempered Lab top bearing allows the
spindle to be virtually “free standing”. It is perfectly normal for the platter to tilt away from the motor
when the belt has not been installed.
Should there be any necessity to replace the bearing oil, any synthetic motor oil of any brand within a
viscosity range of 5W-50 is acceptable.
Note: The zero clearance Well Tempered bearing can rotate for hours without oil. If you wish, you
can complete other adjustments before applying the bearing oil. See Fig (10).